Atx series; aty series electronic analytical balance 66 pages. Auw-d series, auw series, aux series, auy series analytical balance pages. These functions allow for a great variety of applications when used in conjunction with the peripheral units described in this manual. Page 6 However, in the event that any mistakes or omissions are discovered, it may not be possible to correct them immediately.
Reproduction and duplication of whole or part of the content without permission of the company are strictly prohibited. Page 7 You could sustain an electric shock or the product could operate abnormally. Prohibitions If you believe that the balance has failed, contact your Shimadzu representative. Use the balance with the specified power supply and voltage. Using the balance with an incorrect power supply or voltage will lead to fire or trouble with the balance.
Page 8 If the balance has to be stored for a long time, store it in the packaging box in which it was delivered. If you do, the balance may stop working normally. Prohibitions In order to avoid trouble, always connect peripheral devices in accordance with the directions in this manual. SEL M Verify that all of the items are included in the shipping carton.
Display How to read Meaning during weighing In mass display this symbol indicates that the balance Stability is stable.
In menu display, this symbol indicates the symbol current menu setting. Page 14 before shipment. To register other units, refer to Section When the unit is set to 10d, the resolution of the minimum display is decreased by one decimal place.
Unplug the AC adapter from the power outlet and transfer the balance. Disconnecting the power supply or moving the balance during span calibration or check may cause balance failure. Verify that all segments of the display illuminate. If the balance is set to automatically perform span calibration it is executed before zero is displayed.
Page Func. SEL" is displayed. Items in this menu level include span calibration, zero tracking, stability detection band, selection or release of units, automatic PRINT, analog display and Add Load Weighing.
Page Setting Menu 6. AW series only See Section AdJ Enters the next menu level time setting mode. Select the input and output format in this menu. Five preset configurations are available. Select a standard format to set the registered baud rate, parity and bit length , stop bit, delimiter, and data format all at the same time.
When this format is set, the balance will send Page Unit. Span calibration starts at this point. Procedure 1 Warm-up the balance. See Section 3.
When "FUnC. Release of the Measurement Unit Perform operations 1 to 3 above to display the units. Page Solid Specific Gravity The unit for solid specific gravity is " , d. Page Liquid Specific Gravity The display unit for liquid specific gravity is "d. Page Auto Print After that, the displayed value is output whenever it is stabilized even if a different sample is loaded. The stability symbol illuminates when the current setting is displayed.
The stability symbol illuminates to indicate the current setting. The [MENU] and symbols are displayed to indicate numeric value entry. Installation Explanatory operation sheet Pan supporter Anti-draft ring Instruction manual Balance main body AC adapter Adapter cable holder In-use protective cover Verify that there has been no damage and that the following standard packing items are present.
Con- tact your local distributor in case of damaged or missing items. Standard packed items and quantity Standard packed items quantity Peel the protective sheet of adhesive off the adapter cable holder , and stick it on the back of the balance as shown in the figure.
Place the balance main body on the installation site. Page 24 4. Installation Attach the In-use protective cover. When the key panel and the display must be pro- tected from dirt and wear, place the cover over the key panel.
Note Using a verified balance as a legal measuring instrument in the EU: Legal regulations require a verified balance be sealed. Page Turning On The Power 4. Place the AC adapter cable as shown in figure and hold it with the adapter cable holder. Plug the AC adapter to the power outlet. Page Span Calibration 4.
The balance must be connected to power and warmed up for at least one hour prior to span calibration and use as a legal measuring instrument. Page 27 4. Press the [CAL] key once. The zero display will blink. Stability is confirmed after about 30 seconds and Example the value of the weight that should be loaded will blink. Basic Operation Read Chapters 1 to 5 for basic but proper operation of the balance.
Note Before using the balance, warm up thoroughly at least one hour and cali- brate. Page 29 5. Page Changing The Unit Display 0.
When measurement exceeds the small range capacity 82g for AUWD, 42g for AUWD during use of the small range, display automatically switches to the large range. Page 32 5. Avoid the location where vibration from any machinery is transmitted. Corners of a room are less subject to influence of vibration. Do not use the door of the room. Do not allow other people enter, exit or move in the room.
Open glass door minimum. Page Windowsdirect Function 6. Connection is by RSC cable specified by Shimadzu. If bi-directional communication software is used: WindowsDirect function should be turned off. Page Setting Up The Computer 6. D-sub9 D-sub25 D-sub9 D-sub25 A cable of hte 1 wiring is available as an optional accessory. Page 36 6. Page Start And Checking Operation 6. WindowsDirect Function 6. Page 39 6. Page Menu Item Selection 7.
Menu Item Selection 7. Page Menu Item Selection Procedures 7. The menu can be entered by pressing the [CAL] key from the mass display. Page 42 7. Displayed as abbreviations are the three kinds of environmental settings see Page Menu Lock 7.
This is called Menu Lock. WindowsDirect settings also lock. The menu lock is set with the following proce- dure. Set the clock before use of Clock-CAL Page Date Output Style 8. Page Time 8. Page Display Settings 9. Display Settings 9. This bar graph display can be turned on or off. The last decimal place will be rounded and removed from the display.
The backlight can be switched on and off. Page Calibration Calibration Page Types Of Calibration Adjustment of the balance sensitivity using two weight values, zero and near-capacity Calibration test..
Comparing the current calibration mass reading to the calibration mass reading after the last span calibration. Page Executing Calibration Also, make sure that nothing is on the pan and ensure conditions free from the influence of vibrations or wind. From the mass display, press the [CAL] key once. Page Calibration Settings Preset calibration method will be called with only one key touch from the mass display for convenience of frequent use.
If PSC turned ON, when there is a temperature change that would influence sensitivity, span calibra- tion executes automatically to maintain the sensitivity of the balance. Page 59 Clock-CAL is a very convenient function, when cali- bration reports are desired for regular calibrations, or to schedule span calibrations during break times to avoid interruption of measurement work.
Page 61 The built-in calibration weight is already calibrated before shipping but the operator can also calibrate the built-in calibration weight using their own external calibration weights. An optional electronic printer see Combination with Clock-CAL function see Page Balance Id Setting Page Date Printout Setting Page Environment Settings Environment Settings The response and other settings can be changed to adapt to the installation environment for example, unavoidable vibrations or air currents or measurement uses for example, depending on whether solid objects, liquids, or powders are to be measured.
Page High-Stability Mode Environment Settings Anti-convection mode adjusts the timing of appear- ance of the stability mark. Note that when Anti-convec- tion mode is selected, the stability mark will take longer to appear. Page 70 Page Stability Detection Band The condition for judging stability is user-selectable. When the stability detection band is set to 1, the stabil- ity mark appears when the mass display stays within 1 count for a set period of time.
Page Zero Tracking When measuring very slow change in mass such as liquid droplets and evaporation processes, it is recommended to turn zero tracking OFF. Page Stability Mark Lighting Timing Page Units Units Units that are registered beforehand can be called by simply pressing the [UNIT] key when in mass display.
The default units are gram, percentage, PCS, and carat. Page 75 Register percentage unit beforehand. See Percentage unit is registered by default. Therefore, registration is not required if the default setting has not been changed. Page Application Functions Application Functions PCS is registered by default. There- fore, registration is not required if the default set- ting has not been changed. Page Solid Specific Gravity Measurement The following is the procedure when using a hanging pan, a tank and a table allowing below balance weighing, prepared by the operator.
Page 79 Application Functions e Select either the hold display mode or the con- tinuous display mode for the specific gravity value display. Page 80 Application Functions Place the items to be measured on the Example immersed hanging pan. The display shows the weight value in water.
Press the [CAL] key to Example show the specific gravity value in the set specific gravity value display mode. Page Liquid Density Measurement Page 82 Page 83 Application Functions Place the sinker on the immersed hanging pan. Example The display shows the weight value in liquid. Press the [CAL] key to show the liquid density in Hold display mode example the set specific gravity value display mode.
Page Auto Print This function can be combined with WindowsDirect see 6. Page 86 Page Add-On Mode This function automati- cally output the measurement valve and tare after a sample is placed on the pan and the stability mark displays. Page 88 Application Functions Operating Add-on Mode When the Add-on Mode is set on and ready for start, the Add-on symbol and the Standby mark are illumi- Ready for start nated in the mass display.